{"Entry":{"collection":"protocol","key":"functioncallresponse-b","name":"FunctionCallResponse","aliases":["FunctionCallResponse","Byte1('V')"],"metadata":{"aliases":["FunctionCallResponse","Byte1('V')"],"category":"Backend messages","content_hash":"3a3410c25b6db2be702a670a743d3ff82cf664153c423ee610733eb8935bd4e3","imported_at":"2026-09-30T00:40:44.473404+08:00","name":"FunctionCallResponse","name_zh":"","slug":"functioncallresponse-b","summary":"FunctionCallResponse is a backend protocol message. Identifies the message as a function call result."}},"Definition":{"Collection":"protocol","Key":"functioncallresponse-b","SourceDatabase":"center","Version":"18","SourceTable":"protocol_message","SourceKey":"functioncallresponse-b","SourceRevision":"555610c24d53e4316da5b7d3fc25c279d96856d5e0e23ee308c328c5fa881d9f","Facts":{"comparison_data":{"direction":"B","fields":[{"description":"Identifies the message as a function call result.","format":"Byte1('V')"},{"description":"Length of message contents in bytes, including self.","format":"Int32"},{"description":"The length of the function result value, in bytes (this count does not include itself). Can be zero. As a special case, -1 indicates a NULL function result. No value bytes follow in the NULL case.","format":"Int32"},{"description":"The value of the function result, in the format indicated by the associated format code. n is the above length.","format":"Byte n"}]},"comparison_hash":"7ca7919d5142efa3f55c4fc176d38ff2e08dc9c7b307130d14f07ce9e0dce54d","description":["FunctionCallResponse is a backend protocol message. Identifies the message as a function call result."],"direction":"B","facts":[{"label":"Direction","value":"Backend → frontend"},{"label":"First wire field","value":"Byte1('V')"},{"label":"Field entries","value":"4"},{"label":"Documented flow contexts","value":"Function Call"}],"fields":[{"description":"Identifies the message as a function call result.","format":"Byte1('V')"},{"description":"Length of message contents in bytes, including self.","format":"Int32"},{"description":"The length of the function result value, in bytes (this count does not include itself). Can be zero. As a special case, -1 indicates a NULL function result. No value bytes follow in the NULL case.","format":"Int32"},{"description":"The value of the function result, in the format indicated by the associated format code. n is the above length.","format":"Byte n"}],"manual_html":"\u003cdl\u003e\u003cdd\u003e\n\u003cdiv class=\"variablelist\"\u003e\n\u003cdl class=\"variablelist\"\u003e\n\u003cdt\u003e\u003cspan class=\"term\"\u003eByte1('V')\u003c/span\u003e\u003c/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eIdentifies the message as a function call result.\u003c/p\u003e\n\u003c/dd\u003e\n\u003cdt\u003e\u003cspan class=\"term\"\u003eInt32\u003c/span\u003e\u003c/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eLength of message contents in bytes, including self.\u003c/p\u003e\n\u003c/dd\u003e\n\u003cdt\u003e\u003cspan class=\"term\"\u003eInt32\u003c/span\u003e\u003c/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eThe length of the function result value, in bytes (this count does not include itself). Can be zero. As a special case, -1 indicates a NULL function result. No value bytes follow in the NULL case.\u003c/p\u003e\n\u003c/dd\u003e\n\u003cdt\u003e\u003cspan class=\"term\"\u003eByte\u003cem class=\"replaceable\"\u003e\u003ccode\u003en\u003c/code\u003e\u003c/em\u003e\u003c/span\u003e\u003c/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eThe value of the function result, in the format indicated by the associated format code. \u003cem class=\"replaceable\"\u003e\u003ccode\u003en\u003c/code\u003e\u003c/em\u003e is the above length.\u003c/p\u003e\n\u003c/dd\u003e\n\u003c/dl\u003e\n\u003c/div\u003e\n\u003c/dd\u003e\u003c/dl\u003e","manual_path":"/docs/18/protocol-message-formats.html","related":[{"label":"Protocol flow and exchange examples","url":"/docs/18/protocol-flow.html"},{"label":"Protocol overview","url":"/docs/18/protocol-overview.html"},{"label":"Function Call","url":"/docs/18/protocol-flow.html#PROTOCOL-FLOW-FUNCTION-CALL"}],"release":{"channel":"stable","label":"18.6","major":"18","ref":"https://ftp.postgresql.org/pub/source/v18.6/postgresql-18.6.tar.bz2","revision":"555610c24d53e4316da5b7d3fc25c279d96856d5e0e23ee308c328c5fa881d9f"},"sections":[{"paragraphs":["The complete definition below retains repetition, counts and conditional fields. A numbered table row is a documented field definition, not a fixed byte offset. Integer encodings and flow rules follow the same-version protocol chapter."],"title":"Framing and repetition"}],"signature":"FunctionCallResponse (B)","sources":[{"label":"PostgreSQL 18 English manual","path":"protocol-message-formats.html","sha256":"53f37652ac2c089e30ada87d8aee7bdd0f26695b03f275302e526a807d2a1f23","url":"/docs/18/protocol-message-formats.html#PROTOCOL-MESSAGE-FORMATS-FUNCTIONCALLRESPONSE"}],"tables":[{"columns":[{"key":"c0","label":"Position"},{"key":"c1","label":"Format"},{"key":"c2","label":"Meaning"}],"key":"fields","rows":[{"c0":"1","c1":"Byte1('V')","c2":"Identifies the message as a function call result."},{"c0":"2","c1":"Int32","c2":"Length of message contents in bytes, including self."},{"c0":"3","c1":"Int32","c2":"The length of the function result value, in bytes (this count does not include itself). Can be zero. As a special case, -1 indicates a NULL function result. No value bytes follow in the NULL case."},{"c0":"4","c1":"Byte n","c2":"The value of the function result, in the format indicated by the associated format code. n is the above length."}],"title":"Wire fields in documented order"}]},"ManualEvidence":{"manual_path":"/docs/18/protocol-message-formats.html","release":{"channel":"stable","label":"18.6","major":"18","ref":"https://ftp.postgresql.org/pub/source/v18.6/postgresql-18.6.tar.bz2","revision":"555610c24d53e4316da5b7d3fc25c279d96856d5e0e23ee308c328c5fa881d9f"},"sources":[{"label":"PostgreSQL 18 English manual","path":"protocol-message-formats.html","sha256":"53f37652ac2c089e30ada87d8aee7bdd0f26695b03f275302e526a807d2a1f23","url":"/docs/18/protocol-message-formats.html#PROTOCOL-MESSAGE-FORMATS-FUNCTIONCALLRESPONSE"}]},"MeasuredEvidence":{}},"Text":{"Collection":"protocol","Key":"functioncallresponse-b","SourceDatabase":"center","Version":"18","Locale":"en","Title":"FunctionCallResponse","Summary":"FunctionCallResponse is a backend protocol message. Identifies the message as a function call result.","BodyHTML":"\u003cdl\u003e\u003cdd\u003e\n\u003cdiv\u003e\n\u003cdl\u003e\n\u003cdt\u003e\u003cspan\u003eByte1(\u0026#39;V\u0026#39;)\u003c/span\u003e\u003c/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eIdentifies the message as a function call result.\u003c/p\u003e\n\u003c/dd\u003e\n\u003cdt\u003e\u003cspan\u003eInt32\u003c/span\u003e\u003c/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eLength of message contents in bytes, including self.\u003c/p\u003e\n\u003c/dd\u003e\n\u003cdt\u003e\u003cspan\u003eInt32\u003c/span\u003e\u003c/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eThe length of the function result value, in bytes (this count does not include itself). Can be zero. As a special case, -1 indicates a NULL function result. No value bytes follow in the NULL case.\u003c/p\u003e\n\u003c/dd\u003e\n\u003cdt\u003e\u003cspan\u003eByte\u003cem\u003e\u003ccode\u003en\u003c/code\u003e\u003c/em\u003e\u003c/span\u003e\u003c/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eThe value of the function result, in the format indicated by the associated format code. \u003cem\u003e\u003ccode\u003en\u003c/code\u003e\u003c/em\u003e is the above length.\u003c/p\u003e\n\u003c/dd\u003e\n\u003c/dl\u003e\n\u003c/div\u003e\n\u003c/dd\u003e\u003c/dl\u003e","SourceRevision":"555610c24d53e4316da5b7d3fc25c279d96856d5e0e23ee308c328c5fa881d9f","ContentHash":"b46b1dc8dada0654cbe0e1ecba99a6343cdba5d14d295c547db8a3eab4826132","Payload":{"description":["FunctionCallResponse is a backend protocol message. Identifies the message as a function call result."],"manual_html":"\u003cdl\u003e\u003cdd\u003e\n\u003cdiv class=\"variablelist\"\u003e\n\u003cdl class=\"variablelist\"\u003e\n\u003cdt\u003e\u003cspan class=\"term\"\u003eByte1('V')\u003c/span\u003e\u003c/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eIdentifies the message as a function call result.\u003c/p\u003e\n\u003c/dd\u003e\n\u003cdt\u003e\u003cspan class=\"term\"\u003eInt32\u003c/span\u003e\u003c/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eLength of message contents in bytes, including self.\u003c/p\u003e\n\u003c/dd\u003e\n\u003cdt\u003e\u003cspan class=\"term\"\u003eInt32\u003c/span\u003e\u003c/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eThe length of the function result value, in bytes (this count does not include itself). Can be zero. As a special case, -1 indicates a NULL function result. No value bytes follow in the NULL case.\u003c/p\u003e\n\u003c/dd\u003e\n\u003cdt\u003e\u003cspan class=\"term\"\u003eByte\u003cem class=\"replaceable\"\u003e\u003ccode\u003en\u003c/code\u003e\u003c/em\u003e\u003c/span\u003e\u003c/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eThe value of the function result, in the format indicated by the associated format code. \u003cem class=\"replaceable\"\u003e\u003ccode\u003en\u003c/code\u003e\u003c/em\u003e is the above length.\u003c/p\u003e\n\u003c/dd\u003e\n\u003c/dl\u003e\n\u003c/div\u003e\n\u003c/dd\u003e\u003c/dl\u003e","related":[{"label":"Protocol flow and exchange examples","url":"/docs/18/protocol-flow.html"},{"label":"Protocol overview","url":"/docs/18/protocol-overview.html"},{"label":"Function Call","url":"/docs/18/protocol-flow.html#PROTOCOL-FLOW-FUNCTION-CALL"}],"sections":[{"paragraphs":["The complete definition below retains repetition, counts and conditional fields. A numbered table row is a documented field definition, not a fixed byte offset. Integer encodings and flow rules follow the same-version protocol chapter."],"title":"Framing and repetition"}],"tables":[{"columns":[{"key":"c0","label":"Position"},{"key":"c1","label":"Format"},{"key":"c2","label":"Meaning"}],"key":"fields","rows":[{"c0":"1","c1":"Byte1('V')","c2":"Identifies the message as a function call result."},{"c0":"2","c1":"Int32","c2":"Length of message contents in bytes, including self."},{"c0":"3","c1":"Int32","c2":"The length of the function result value, in bytes (this count does not include itself). Can be zero. As a special case, -1 indicates a NULL function result. No value bytes follow in the NULL case."},{"c0":"4","c1":"Byte n","c2":"The value of the function result, in the format indicated by the associated format code. n is the above length."}],"title":"Wire fields in documented order"}]}},"RequestedLocale":"zh-Hans","Fallback":true,"Versions":["10","11","12","13","14","15","16","17","18","19","20"],"Locales":["en"],"Signatures":null,"Spellings":null,"SQLState":null,"Evidence":null}
