{"Entry":{"collection":"protocol","key":"nodata-b","name":"NoData","aliases":["NoData","Byte1('n')"],"metadata":{"aliases":["NoData","Byte1('n')"],"category":"Backend messages","content_hash":"526867c11d6c44b2abd32b1377c572e23a952f0c02f39b825c74d324eef97433","imported_at":"2026-09-30T00:40:44.481081+08:00","name":"NoData","name_zh":"","slug":"nodata-b","summary":"NoData is a backend protocol message. Identifies the message as a no-data indicator."}},"Definition":{"Collection":"protocol","Key":"nodata-b","SourceDatabase":"center","Version":"18","SourceTable":"protocol_message","SourceKey":"nodata-b","SourceRevision":"555610c24d53e4316da5b7d3fc25c279d96856d5e0e23ee308c328c5fa881d9f","Facts":{"comparison_data":{"direction":"B","fields":[{"description":"Identifies the message as a no-data indicator.","format":"Byte1('n')"},{"description":"Length of message contents in bytes, including self.","format":"Int32(4)"}]},"comparison_hash":"222ed6b6e2df1e7fb820608b1ef098c390ecbb1135aff1b084b4629abdd9e02f","description":["NoData is a backend protocol message. Identifies the message as a no-data indicator."],"direction":"B","facts":[{"label":"Direction","value":"Backend → frontend"},{"label":"First wire field","value":"Byte1('n')"},{"label":"Field entries","value":"2"},{"label":"Documented flow contexts","value":"Extended Query"}],"fields":[{"description":"Identifies the message as a no-data indicator.","format":"Byte1('n')"},{"description":"Length of message contents in bytes, including self.","format":"Int32(4)"}],"manual_html":"\u003cdl\u003e\u003cdd\u003e\n\u003cdiv class=\"variablelist\"\u003e\n\u003cdl class=\"variablelist\"\u003e\n\u003cdt\u003e\u003cspan class=\"term\"\u003eByte1('n')\u003c/span\u003e\u003c/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eIdentifies the message as a no-data indicator.\u003c/p\u003e\n\u003c/dd\u003e\n\u003cdt\u003e\u003cspan class=\"term\"\u003eInt32(4)\u003c/span\u003e\u003c/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eLength of message contents in bytes, including self.\u003c/p\u003e\n\u003c/dd\u003e\n\u003c/dl\u003e\n\u003c/div\u003e\n\u003c/dd\u003e\u003c/dl\u003e","manual_path":"/docs/18/protocol-message-formats.html","related":[{"label":"Protocol flow and exchange examples","url":"/docs/18/protocol-flow.html"},{"label":"Protocol overview","url":"/docs/18/protocol-overview.html"},{"label":"Extended Query","url":"/docs/18/protocol-flow.html#PROTOCOL-FLOW-EXT-QUERY"}],"release":{"channel":"stable","label":"18.6","major":"18","ref":"https://ftp.postgresql.org/pub/source/v18.6/postgresql-18.6.tar.bz2","revision":"555610c24d53e4316da5b7d3fc25c279d96856d5e0e23ee308c328c5fa881d9f"},"sections":[{"paragraphs":["The complete definition below retains repetition, counts and conditional fields. A numbered table row is a documented field definition, not a fixed byte offset. Integer encodings and flow rules follow the same-version protocol chapter."],"title":"Framing and repetition"}],"signature":"NoData (B)","sources":[{"label":"PostgreSQL 18 English manual","path":"protocol-message-formats.html","sha256":"53f37652ac2c089e30ada87d8aee7bdd0f26695b03f275302e526a807d2a1f23","url":"/docs/18/protocol-message-formats.html#PROTOCOL-MESSAGE-FORMATS-NODATA"}],"tables":[{"columns":[{"key":"c0","label":"Position"},{"key":"c1","label":"Format"},{"key":"c2","label":"Meaning"}],"key":"fields","rows":[{"c0":"1","c1":"Byte1('n')","c2":"Identifies the message as a no-data indicator."},{"c0":"2","c1":"Int32(4)","c2":"Length of message contents in bytes, including self."}],"title":"Wire fields in documented order"}]},"ManualEvidence":{"manual_path":"/docs/18/protocol-message-formats.html","release":{"channel":"stable","label":"18.6","major":"18","ref":"https://ftp.postgresql.org/pub/source/v18.6/postgresql-18.6.tar.bz2","revision":"555610c24d53e4316da5b7d3fc25c279d96856d5e0e23ee308c328c5fa881d9f"},"sources":[{"label":"PostgreSQL 18 English manual","path":"protocol-message-formats.html","sha256":"53f37652ac2c089e30ada87d8aee7bdd0f26695b03f275302e526a807d2a1f23","url":"/docs/18/protocol-message-formats.html#PROTOCOL-MESSAGE-FORMATS-NODATA"}]},"MeasuredEvidence":{}},"Text":{"Collection":"protocol","Key":"nodata-b","SourceDatabase":"center","Version":"18","Locale":"en","Title":"NoData","Summary":"NoData is a backend protocol message. Identifies the message as a no-data indicator.","BodyHTML":"\u003cdl\u003e\u003cdd\u003e\n\u003cdiv\u003e\n\u003cdl\u003e\n\u003cdt\u003e\u003cspan\u003eByte1(\u0026#39;n\u0026#39;)\u003c/span\u003e\u003c/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eIdentifies the message as a no-data indicator.\u003c/p\u003e\n\u003c/dd\u003e\n\u003cdt\u003e\u003cspan\u003eInt32(4)\u003c/span\u003e\u003c/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eLength of message contents in bytes, including self.\u003c/p\u003e\n\u003c/dd\u003e\n\u003c/dl\u003e\n\u003c/div\u003e\n\u003c/dd\u003e\u003c/dl\u003e","SourceRevision":"555610c24d53e4316da5b7d3fc25c279d96856d5e0e23ee308c328c5fa881d9f","ContentHash":"eda6a6dbe207324af93d942529d1afdd0fb7c329aa83187c42e1f3da028c4d86","Payload":{"description":["NoData is a backend protocol message. Identifies the message as a no-data indicator."],"manual_html":"\u003cdl\u003e\u003cdd\u003e\n\u003cdiv class=\"variablelist\"\u003e\n\u003cdl class=\"variablelist\"\u003e\n\u003cdt\u003e\u003cspan class=\"term\"\u003eByte1('n')\u003c/span\u003e\u003c/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eIdentifies the message as a no-data indicator.\u003c/p\u003e\n\u003c/dd\u003e\n\u003cdt\u003e\u003cspan class=\"term\"\u003eInt32(4)\u003c/span\u003e\u003c/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eLength of message contents in bytes, including self.\u003c/p\u003e\n\u003c/dd\u003e\n\u003c/dl\u003e\n\u003c/div\u003e\n\u003c/dd\u003e\u003c/dl\u003e","related":[{"label":"Protocol flow and exchange examples","url":"/docs/18/protocol-flow.html"},{"label":"Protocol overview","url":"/docs/18/protocol-overview.html"},{"label":"Extended Query","url":"/docs/18/protocol-flow.html#PROTOCOL-FLOW-EXT-QUERY"}],"sections":[{"paragraphs":["The complete definition below retains repetition, counts and conditional fields. A numbered table row is a documented field definition, not a fixed byte offset. Integer encodings and flow rules follow the same-version protocol chapter."],"title":"Framing and repetition"}],"tables":[{"columns":[{"key":"c0","label":"Position"},{"key":"c1","label":"Format"},{"key":"c2","label":"Meaning"}],"key":"fields","rows":[{"c0":"1","c1":"Byte1('n')","c2":"Identifies the message as a no-data indicator."},{"c0":"2","c1":"Int32(4)","c2":"Length of message contents in bytes, including self."}],"title":"Wire fields in documented order"}]}},"RequestedLocale":"zh-Hans","Fallback":true,"Versions":["10","11","12","13","14","15","16","17","18","19","20"],"Locales":["en"],"Signatures":null,"Spellings":null,"SQLState":null,"Evidence":null}
