{"Entry":{"collection":"protocol","key":"noticeresponse-b","name":"NoticeResponse","aliases":["NoticeResponse","Byte1('N')"],"metadata":{"aliases":["NoticeResponse","Byte1('N')"],"category":"Backend messages","content_hash":"a1f5c6fae9a2fa8cb7bba01fd993ee5b5663fb0a3853aa0d608a405a5c37563e","imported_at":"2026-09-30T00:40:44.484555+08:00","name":"NoticeResponse","name_zh":"","slug":"noticeresponse-b","summary":"NoticeResponse is a backend protocol message. Identifies the message as a notice."}},"Definition":{"Collection":"protocol","Key":"noticeresponse-b","SourceDatabase":"center","Version":"18","SourceTable":"protocol_message","SourceKey":"noticeresponse-b","SourceRevision":"555610c24d53e4316da5b7d3fc25c279d96856d5e0e23ee308c328c5fa881d9f","Facts":{"comparison_data":{"direction":"B","fields":[{"description":"Identifies the message as a notice.","format":"Byte1('N')"},{"description":"Length of message contents in bytes, including self.","format":"Int32"},{"description":"A code identifying the field type; if zero, this is the message terminator and no string follows. The presently defined field types are listed in Section 54.8 . Since more field types might be added in future, frontends should silently ignore fields of unrecognized type.","format":"Byte1"},{"description":"The field value.","format":"String"}]},"comparison_hash":"c2c8e73ba67779cf4f3276f3b51cc99b20d0ca44b28f9814677b93608d030ced","description":["NoticeResponse is a backend protocol message. Identifies the message as a notice."],"direction":"B","facts":[{"label":"Direction","value":"Backend → frontend"},{"label":"First wire field","value":"Byte1('N')"},{"label":"Field entries","value":"4"},{"label":"Documented flow contexts","value":"Start-up; Simple Query; Function Call; COPY Operations; Asynchronous Operations"}],"fields":[{"description":"Identifies the message as a notice.","format":"Byte1('N')"},{"description":"Length of message contents in bytes, including self.","format":"Int32"},{"description":"A code identifying the field type; if zero, this is the message terminator and no string follows. The presently defined field types are listed in Section 54.8 . Since more field types might be added in future, frontends should silently ignore fields of unrecognized type.","format":"Byte1"},{"description":"The field value.","format":"String"}],"manual_html":"\u003cdl\u003e\u003cdd\u003e\n\u003cdiv class=\"variablelist\"\u003e\n\u003cdl class=\"variablelist\"\u003e\n\u003cdt\u003e\u003cspan class=\"term\"\u003eByte1('N')\u003c/span\u003e\u003c/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eIdentifies the message as a notice.\u003c/p\u003e\n\u003c/dd\u003e\n\u003cdt\u003e\u003cspan class=\"term\"\u003eInt32\u003c/span\u003e\u003c/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eLength of message contents in bytes, including self.\u003c/p\u003e\n\u003c/dd\u003e\n\u003c/dl\u003e\n\u003c/div\u003e\n\u003cp\u003eThe message body consists of one or more identified fields, followed by a zero byte as a terminator. Fields can appear in any order. For each field there is the following:\u003c/p\u003e\n\u003cdiv class=\"variablelist\"\u003e\n\u003cdl class=\"variablelist\"\u003e\n\u003cdt\u003e\u003cspan class=\"term\"\u003eByte1\u003c/span\u003e\u003c/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eA code identifying the field type; if zero, this is the message terminator and no string follows. The presently defined field types are listed in \u003ca class=\"xref\" href=\"/docs/18/protocol-error-fields.html\" title=\"54.8. Error and Notice Message Fields\"\u003eSection 54.8\u003c/a\u003e. Since more field types might be added in future, frontends should silently ignore fields of unrecognized type.\u003c/p\u003e\n\u003c/dd\u003e\n\u003cdt\u003e\u003cspan class=\"term\"\u003eString\u003c/span\u003e\u003c/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eThe field value.\u003c/p\u003e\n\u003c/dd\u003e\n\u003c/dl\u003e\n\u003c/div\u003e\n\u003c/dd\u003e\u003c/dl\u003e","manual_path":"/docs/18/protocol-message-formats.html","related":[{"label":"Protocol flow and exchange examples","url":"/docs/18/protocol-flow.html"},{"label":"Protocol overview","url":"/docs/18/protocol-overview.html"},{"label":"Start-up","url":"/docs/18/protocol-flow.html#PROTOCOL-FLOW-START-UP"},{"label":"Simple Query","url":"/docs/18/protocol-flow.html#PROTOCOL-FLOW-SIMPLE-QUERY"},{"label":"Function Call","url":"/docs/18/protocol-flow.html#PROTOCOL-FLOW-FUNCTION-CALL"},{"label":"COPY Operations","url":"/docs/18/protocol-flow.html#PROTOCOL-COPY"},{"label":"Asynchronous Operations","url":"/docs/18/protocol-flow.html#PROTOCOL-ASYNC"}],"release":{"channel":"stable","label":"18.6","major":"18","ref":"https://ftp.postgresql.org/pub/source/v18.6/postgresql-18.6.tar.bz2","revision":"555610c24d53e4316da5b7d3fc25c279d96856d5e0e23ee308c328c5fa881d9f"},"sections":[{"paragraphs":["The complete definition below retains repetition, counts and conditional fields. A numbered table row is a documented field definition, not a fixed byte offset. Integer encodings and flow rules follow the same-version protocol chapter."],"title":"Framing and repetition"}],"signature":"NoticeResponse (B)","sources":[{"label":"PostgreSQL 18 English manual","path":"protocol-message-formats.html","sha256":"53f37652ac2c089e30ada87d8aee7bdd0f26695b03f275302e526a807d2a1f23","url":"/docs/18/protocol-message-formats.html#PROTOCOL-MESSAGE-FORMATS-NOTICERESPONSE"}],"tables":[{"columns":[{"key":"c0","label":"Position"},{"key":"c1","label":"Format"},{"key":"c2","label":"Meaning"}],"key":"fields","rows":[{"c0":"1","c1":"Byte1('N')","c2":"Identifies the message as a notice."},{"c0":"2","c1":"Int32","c2":"Length of message contents in bytes, including self."},{"c0":"3","c1":"Byte1","c2":"A code identifying the field type; if zero, this is the message terminator and no string follows. The presently defined field types are listed in Section 54.8 . Since more field types might be added in future, frontends should silently ignore fields of unrecognized type."},{"c0":"4","c1":"String","c2":"The field value."}],"title":"Wire fields in documented order"}]},"ManualEvidence":{"manual_path":"/docs/18/protocol-message-formats.html","release":{"channel":"stable","label":"18.6","major":"18","ref":"https://ftp.postgresql.org/pub/source/v18.6/postgresql-18.6.tar.bz2","revision":"555610c24d53e4316da5b7d3fc25c279d96856d5e0e23ee308c328c5fa881d9f"},"sources":[{"label":"PostgreSQL 18 English manual","path":"protocol-message-formats.html","sha256":"53f37652ac2c089e30ada87d8aee7bdd0f26695b03f275302e526a807d2a1f23","url":"/docs/18/protocol-message-formats.html#PROTOCOL-MESSAGE-FORMATS-NOTICERESPONSE"}]},"MeasuredEvidence":{}},"Text":{"Collection":"protocol","Key":"noticeresponse-b","SourceDatabase":"center","Version":"18","Locale":"en","Title":"NoticeResponse","Summary":"NoticeResponse is a backend protocol message. Identifies the message as a notice.","BodyHTML":"\u003cdl\u003e\u003cdd\u003e\n\u003cdiv\u003e\n\u003cdl\u003e\n\u003cdt\u003e\u003cspan\u003eByte1(\u0026#39;N\u0026#39;)\u003c/span\u003e\u003c/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eIdentifies the message as a notice.\u003c/p\u003e\n\u003c/dd\u003e\n\u003cdt\u003e\u003cspan\u003eInt32\u003c/span\u003e\u003c/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eLength of message contents in bytes, including self.\u003c/p\u003e\n\u003c/dd\u003e\n\u003c/dl\u003e\n\u003c/div\u003e\n\u003cp\u003eThe message body consists of one or more identified fields, followed by a zero byte as a terminator. Fields can appear in any order. For each field there is the following:\u003c/p\u003e\n\u003cdiv\u003e\n\u003cdl\u003e\n\u003cdt\u003e\u003cspan\u003eByte1\u003c/span\u003e\u003c/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eA code identifying the field type; if zero, this is the message terminator and no string follows. The presently defined field types are listed in \u003ca href=\"/docs/18/protocol-error-fields.html\" rel=\"nofollow\"\u003eSection 54.8\u003c/a\u003e. Since more field types might be added in future, frontends should silently ignore fields of unrecognized type.\u003c/p\u003e\n\u003c/dd\u003e\n\u003cdt\u003e\u003cspan\u003eString\u003c/span\u003e\u003c/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eThe field value.\u003c/p\u003e\n\u003c/dd\u003e\n\u003c/dl\u003e\n\u003c/div\u003e\n\u003c/dd\u003e\u003c/dl\u003e","SourceRevision":"555610c24d53e4316da5b7d3fc25c279d96856d5e0e23ee308c328c5fa881d9f","ContentHash":"985853ea4cc90a53bf5446b2212f12ce42e8594f14cdec4dda8ba150189b0022","Payload":{"description":["NoticeResponse is a backend protocol message. Identifies the message as a notice."],"manual_html":"\u003cdl\u003e\u003cdd\u003e\n\u003cdiv class=\"variablelist\"\u003e\n\u003cdl class=\"variablelist\"\u003e\n\u003cdt\u003e\u003cspan class=\"term\"\u003eByte1('N')\u003c/span\u003e\u003c/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eIdentifies the message as a notice.\u003c/p\u003e\n\u003c/dd\u003e\n\u003cdt\u003e\u003cspan class=\"term\"\u003eInt32\u003c/span\u003e\u003c/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eLength of message contents in bytes, including self.\u003c/p\u003e\n\u003c/dd\u003e\n\u003c/dl\u003e\n\u003c/div\u003e\n\u003cp\u003eThe message body consists of one or more identified fields, followed by a zero byte as a terminator. Fields can appear in any order. For each field there is the following:\u003c/p\u003e\n\u003cdiv class=\"variablelist\"\u003e\n\u003cdl class=\"variablelist\"\u003e\n\u003cdt\u003e\u003cspan class=\"term\"\u003eByte1\u003c/span\u003e\u003c/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eA code identifying the field type; if zero, this is the message terminator and no string follows. The presently defined field types are listed in \u003ca class=\"xref\" href=\"/docs/18/protocol-error-fields.html\" title=\"54.8. Error and Notice Message Fields\"\u003eSection 54.8\u003c/a\u003e. Since more field types might be added in future, frontends should silently ignore fields of unrecognized type.\u003c/p\u003e\n\u003c/dd\u003e\n\u003cdt\u003e\u003cspan class=\"term\"\u003eString\u003c/span\u003e\u003c/dt\u003e\n\u003cdd\u003e\n\u003cp\u003eThe field value.\u003c/p\u003e\n\u003c/dd\u003e\n\u003c/dl\u003e\n\u003c/div\u003e\n\u003c/dd\u003e\u003c/dl\u003e","related":[{"label":"Protocol flow and exchange examples","url":"/docs/18/protocol-flow.html"},{"label":"Protocol overview","url":"/docs/18/protocol-overview.html"},{"label":"Start-up","url":"/docs/18/protocol-flow.html#PROTOCOL-FLOW-START-UP"},{"label":"Simple Query","url":"/docs/18/protocol-flow.html#PROTOCOL-FLOW-SIMPLE-QUERY"},{"label":"Function Call","url":"/docs/18/protocol-flow.html#PROTOCOL-FLOW-FUNCTION-CALL"},{"label":"COPY Operations","url":"/docs/18/protocol-flow.html#PROTOCOL-COPY"},{"label":"Asynchronous Operations","url":"/docs/18/protocol-flow.html#PROTOCOL-ASYNC"}],"sections":[{"paragraphs":["The complete definition below retains repetition, counts and conditional fields. A numbered table row is a documented field definition, not a fixed byte offset. Integer encodings and flow rules follow the same-version protocol chapter."],"title":"Framing and repetition"}],"tables":[{"columns":[{"key":"c0","label":"Position"},{"key":"c1","label":"Format"},{"key":"c2","label":"Meaning"}],"key":"fields","rows":[{"c0":"1","c1":"Byte1('N')","c2":"Identifies the message as a notice."},{"c0":"2","c1":"Int32","c2":"Length of message contents in bytes, including self."},{"c0":"3","c1":"Byte1","c2":"A code identifying the field type; if zero, this is the message terminator and no string follows. The presently defined field types are listed in Section 54.8 . Since more field types might be added in future, frontends should silently ignore fields of unrecognized type."},{"c0":"4","c1":"String","c2":"The field value."}],"title":"Wire fields in documented order"}]}},"RequestedLocale":"zh-Hans","Fallback":true,"Versions":["10","11","12","13","14","15","16","17","18","19","20"],"Locales":["en"],"Signatures":null,"Spellings":null,"SQLState":null,"Evidence":null}
